Features:
This product is small in size and light in weight. It is made of high-quality anti-ultraviolet materials and has a long service life. It uses a high-sensitivity probe with stable signal and high accuracy. The key components adopt imported components, which are stable and reliable, and have the characteristics of wide measurement range, good linearity, good waterproof performance, convenient use, easy installation, and long transmission distance.
It adopts an integrated design with multiple collection devices and is easy to install.
Wind speed and direction are measured by ultrasonic principle, no start-up wind speed limit, zero wind speed work, no angle limit, 360° omni-directional, wind speed and wind direction data can be obtained at the same time.
Noise collection, accurate measurement, the range is as high as 30dB~120dB.PM2.5 and PM10
Simultaneous acquisition, range: 0-1000ug/m3, resolution 1ug/m3, unique dual-frequency data acquisition and automatic calibration technology, consistency can reach ±10%.
Measuring the environmental temperature and humidity, the measuring unit is imported from Switzerland, and the measurement is accurate.
Wide range 0-120Kpa air pressure range, applicable to various altitudes.
Use dedicated 485 circuit, stable communication.
Equipment with built-in electronic compass, no direction requirements during installation, horizontal installation.
Equipment Size:
Installation Method:
The installation of equipment without electronic compass is shown in the figure below, and the equipment with built-in electronic compass only needs to be installed horizontally.
Hugging seat installation:
Beam installation:
Interface Description:
DC power supply 10-30V power supply. When wiring the 485 signal line, pay attention to the two wires A/B not to be reversed, and the addresses of multiple devices on the bus cannot be conflicted.
Line color |
Illustrate |
|
Power supply |
Brown |
Power is positive(10-30V DC) |
Black |
Power is negative |
|
Communication |
Green |
485-A |
Blue |
485-B |
Main Technical Index:
DC power supply (default) |
10-30VDC |
|
Maximum power consumption |
RS485 output |
1.2W |
Precision |
Wind speed |
±(0.2m/s±0.02*v)(v is the true wind speed) |
Wind direction |
±3° |
|
Humidity |
±3%RH(60%RH,25℃) |
|
Temperature |
±0.5℃(25℃) |
|
Atmospheric pressure |
±0.15Kpa@25℃ 75Kpa |
|
Noise |
±3db |
|
PM10 PM2.5 |
±10%(25℃) |
|
Light intensity |
±7%(25℃) |
|
Range |
Wind speed |
0~60m/s |
Wind direction |
0~359° |
|
Humidity |
0%RH~99%RH |
|
Temperature |
-40℃~+80℃ |
|
Atmospheric pressure |
0-120Kpa |
|
Noise |
30dB~120dB |
|
PM10 PM2.5 |
0-1000ug/m3 |
|
Light intensity |
0~20万Lux |
|
Long-term stability |
Temperature |
≤0.1℃/y |
Humidity |
≤1%/y |
|
Atmospheric pressure |
-0.1Kpa/y |
|
Noise |
≤3db/y |
|
PM10 PM2.5 |
≤1%/y |
|
Light intensity |
≤5%/y |
|
Response time |
Wind speed |
1S |
Wind direction |
1S |
|
Temp & Hum |
≤1s |
|
Atmospheric pressure |
≤1s |
|
Noise |
≤1s |
|
PM10 PM2.5 |
≤90S |
|
Light intensity |
≤0.1s |
|
Output signal |
RS485 output |
RS485 (standard Modbus communication protocol) |